CyFlow™ CD14 PE-Cy5

CyFlow™ CD14 PE-Cy5
Antigen: CD14
Alternative Name: LPS-R
Clone: MEM-15
Application: Flow cytometry
Format/Fluorochrome: PE-Cy5
Laser: Blue, Green, Yellow
Target Species: Human, Non-Human Primates
Field of Interest: Immunophenotyping
Species of Origin: Mouse
Regulatory Status: RUO
Clonality: monoclonal
Emission Maximum: 670 nm
Excitation Maximum: 496 nm, 565 nm
Isotype: IgG1
Order number: CD565869

For Research Use Only
Not for use in diagnostic or therapeutic procedures.

Quantity 100 tests Volume 0.4 ml Immunogen A crude mixture of human urinary proteins... more
CyFlow™ CD14 PE-Cy5
Quantity100 tests
Volume0.4 ml
ImmunogenA crude mixture of human urinary proteins precipitated by ammonium sulphate from the urine of a patient suffering from proteinuria
SpecifityThe mouse monoclonal antibody MEM-15 recognizes CD14 antigen, a 53-55 kDa GPI (glycosylphosphatidylinositol)-linked membrane glycoprotein expressed on monocytes, macrophages and weakly on granulocytes; also expressed by most tissue macrophages. The antibody MEM-15 also reacts with soluble forms of CD14 found in serum and in the urine of some nephrotic patients.
Background InformationCD14 is a 55 kDa GPI-anchored glycoprotein, constitutively expressed on the surface of mature monocytes, macrophages, and neutrophils, where serves as a multifunctional lipopolysaccharide receptor; it is also released to the serum both as a secreted and enzymatically cleaved GPI-anchored form. CD14 binds lipopolysaccharide molecule in a reaction catalyzed by lipopolysaccharide-binding protein (LBP), an acute phase serum protein. The soluble sCD14 is able to discriminate slight structural differences between lipopolysaccharides and is important for neutralization of serum allochthonous lipopolysaccharides by reconstituted lipoprotein particles. CD14 affects allergic, inflammatory and infectious processes.
UsageThe reagent is designed for Flow Cytometry analysis of human blood cells. Recommended usage is 4·µl reagent·/ 100·µl of whole blood or 10^6 cells in a suspension. The content of a vial (0.4 ml) is sufficient for 100 tests.
Storage BufferThe reagent is provided in stabilizing phosphate buffered saline (PBS) solution, pH ≈7.4, containing 0.1% (w/v) sodium azide.
StorageAvoid prolonged exposure to light. Store in the dark at 2-8°C. Do not freeze.
StabilityDo not use after expiration date stamped on vial label.